Operation and maintenance manual

114 SEBU8601-01
Maintenance Section
Fuel System Primary Filter/Water Separator - Drain
Install the Element
g021484
41
Illustration 78
Typ ical exam p le
1. Locate
the thread in the lter element (8) onto the
threads (9). Spin on the element. Do not tighten.
2. Lubri
cate the O ring seal (7) with clean engine oil.
Do NOT ll the bowl with fuel before the assembly
is installed.
3. Do not use a tool in order to install the lter
assembly. Tighten the lter bowl (6) by hand.
Inst
all the lter bowl (6) and align with your
temporary marks (A).
4. Tigh
ten the valve (2) securely. Remove the
container and dispose of the fuel in a safe place.
5. The s
econdary lter element must be replaced at
thesametimeastheprimarylter element. Refer
to the Operation and Maintenance Manual , “Fuel
Sys
tem Filter - Replace”.
In-
line Strainer
The fuel system as an in-line strainer installed before
th
e electric priming pump. Perkins recommended
that the in-line strainer be replaced when required.
Th
e location of the in-line strainer will depend on the
application.
i03980098
Fuel System Primary
Filter/Water
Separator - Drain
Fuel leaked or spilled onto hot surfaces or elec-
trical components can cause a re. To help pre-
vent possible injury, turn the start switch off when
changing fuel lters or water separator elements.
Cleanupfuelspillsimmediately.
NOTICE
Ensure that the engine is stopped before any servicing
or repair is performed.
NOTICE
The water separator can be under suction during nor-
mal engi
ne operation. Ensure that the drain valve is
tightened securely to help prevent air from entering
the fuel system.
1. Place a suitable container under the water
separator in order to catch any uid that might
spill.
Cleanupanyspilleduid.
2. Ensure that the outer body of the lter assembly is
clean
and free from dirt.
g02148370
Illustration 79
Typica l e xample