Operation and maintenance manual
SEBU8601-01 111
Maintenance Section
Fuel System - Prime
Ensure that the
engine is stopped. Ensure that the
battery disconnect switch is in the OFF position.
Ensure that the cooling system is full. The clearance
between the co
ver (1) and the fan (2) will require
checking. The gap (A) between the edge of the cover
and the tip of the fan blade must be checked in four
equally spac
ed positions.
g01348394
Illustration 75
Adjustment of the cover will change the clearance
(gap) between the edge of the cover and the tip of
the fan blade. Ensure that the cover is centralized to
the fan.
The clearance (A) must be 11 ± 2 mm
(0.43307 ± 0.07874 inch).
i03906114
Fuel System - Prime
Note: Refer to Systems Operation, Testing,
and Adjusting, “Cleanliness of Fuel System
Components” for d etailed information on the
standards of cleanliness that must be obse rved
during ALL work on the fuel system.
Ensure that all adjustments and repairs are performed
by authorized personnel that have had the correct
training.