Operation and maintenance manual

106 SEBU8601-01
Maintenance Section
Engine Crankcase Breather Element - Replace
g02346497
Illustration 66
Typ ical exam p le
(B) Alignmen t position
4. Remove the old seal (4) and install a new seal.
Note: The cut away from section (5) in the top cap
allows access to the seal.
5. Install a new lter element into the breather body
(3). Align position (A) on the lter element to
position (B) on the top cap.
g02346577
Illustration 67
Typ ical exam p le
6. Install the top cap (1). Rotate the top cap by hand
clockwise until the top cap locks into the locked
position (C) on the breather body.
7. Remove the cont
ainer.
Bottom Servic
e
Ensure that dirt cannot enter the breather assembly.
g02346498
Illustration 68
(X) Alignment ma rk
(Y) Alignment ma rk
1. Ensure that the outside body of the breather
assembly is clean and free from damage. Place
a container under the breather.
2. Remove the tube connection (1). Ensure that
dirt cannot enter the tube connection. Note the
position of the alignment marks (X and Y). Rotate
the bottom cap (2) counterclockwise in order to
release the cap and the lter element (4) from the
breather body (3).