Operation and maintenance manual
SEBU8601-01 103
Maintenance Section
Engine Air Cleaner Element (Single Element) - Inspect/Replace
Pressurized Ai
r
Personal injury can result from air pressure.
Personal injury can result without following prop-
er procedure. When using pressure air, wear a pro-
tective face shield and protective clothing.
Maximum air pressure a t the nozzle must be less
than 205 kPa (30 psi ) for cleaning purposes.
Pressurizedaircanbeusedtocleanprimaryair
cleaner elements that have not been cleaned more
than three times. Use filtered, dry air with a maximum
pressure of 207 kPa (30 psi). Pressurized air will not
remove deposits of carbon and oil.
g00281692
Illustration 61
Note: When the primary air cleaner elements are
cleaned, always begin with the clean side (inside)
in order to force dirt particles toward the dirty side
(outside).
Aim the air hose so that air flows along the length of
the filter. Follow the direction of the paper pleats in
order to prevent damage to the pleats. Do not aim
the air directly at the face of the paper pleats.
Note: Refer to “Inspecting the Primary Air Cleaner
Elements”.
Vacuum C leaning
Vacuum cleaning is a good method for removing
accumulated dirt from the dirty side (outside) of a
primary air cleaner element. Vacuum cleaning is
especially useful for cleaning primary air cleaner
elements which require daily cleaning because of a
dry, dusty environment.
Cleaning from the clean side (inside) with pressurized
air is recommended prior to vacuum cleaning the
dirty side (outside) of a primary air cleaner element.
Note: Refer to “
Inspecting the Primary Air Cleaner
Elements”.
Inspecting th
e Primary Air Cleaner
Elemen ts
g00281693
Illustration 62
Inspect
the clean, dry primary air cleaner element.
Use a 60 watt blue light in a dark room or in a similar
facility. Place the blue light in the primary air cleaner
element
. Rotate the primary air cleaner element.
Inspect the primary air cleaner element for tears
and/or holes. Inspect the primary air cleaner element
for lig
ht that may show through the filter material. If it
is necessary in order to confirm the result, compare
the primary air cleaner element to a new primary air
cleane
r element that has the same part number.
Do not use a primary air cleaner element that has
any te
ars and/or holes in the filter material. Do not
use a primary air cleaner element with damaged
pleats, gaskets or seals. Discard damaged primary
air cl
eaner elements.
i02152042
Engi
ne Air Cleaner
Element (Single Elem ent) -
Inspect/Replace
Ref
er to Operation and Maintenance Manual, “Engine
Air Cleaner Service Indicator-Inspect”.
NOTICE
Never run the engine without an air cleaner element
installed. Never run the engine with a damaged air
cleaner element. Do not use air cleaner elements with
damaged pleats, gaskets or seals. Dirt entering the
engine causes premature wear and damage to engine
components. Air cleaner elements help to prevent air-
borne debris from entering the air inlet.