Operation and maintenance manual
100 SEBU8601-01
Maintenance Section
Diesel Particulate Filter - Clean
g01950241
Illustration 58
Typ ical exam p le
Inspect the damper and replace the damper for any
of the following reasons:
•
The damper is dented, cracked, or leaking.
For information on removal of the crankshaft damper,
refer to Disassembly and Assembly, “Vibration
Damper and Pulley - Remove and Install”.
i04087370
Diesel Particulate Filter - Clean
Wear goggles, gloves, protective clothing, and
a National Institute for Occupational Safety and
Health (NIOSH) approved P95 or N95 half-face
respirator when handling a used Diesel Particu-
late Filter or Catalytic Converter Muffler. Failure
to do so could result in personal injury.
The muffler, catalytic converter/muffler, and diesel
particulate filter will become extremely hot during
engine operation. A hot muffler, catalytic convert-
er/muffler and diesel particulate filter can cause
serious burns. Allow adequate cooling time before
workingonornearthemuffler, catalytic convert-
er/muffler and diesel particulate filter.
g01949226
Illustration 59
Typica l e xample
•
DPF__________________________ Diesel Particulate Filter
Contact your Perkins dealer, or your Perkins
distributor. New torca clamps (1) must be installed
on the DPF.
For information on removal of the DPF, refer to
Disassembly and Assembly, “DPF - Remove”. Also,
refer to System Operation Testing and Adjusting,
“Diesel Particulate Filter - Clean”.
•
Onlyultralowsufurdieselfuelcanbeusedinan
application that has an aftertreatment regeneration
device. The use of other fuel will damage your
engine system.
•
The engine must be operated on CJ-4 specification
of engine oil.
i02151646
Driven Equipm en t - Ch eck
Refer to the OEM specifications for more information
on the following maintenance recommendations for
thedrivenequipment:
•
Inspection
•
Adjustment
•
Lubrication
•