8.2.2.6 Tank Header Connection (Remote PEU Only)
For those customers requiring a remote mounted PEU the customer is
responsible for the connection of the Perkins supplied header unit back to the
PEU unit. The header unit comes supplied with a flying lead connection that
requires connection to the mating 3 way interface connector on the PEU as
shown in figure 8.12.
Figure 8.12 Remote PEU Header connection
If the distance between the header unit and the PEU is greater than 500mm
then the customer must fit an interconnect harness between the Header unit
connector and the PEU 3 way interface connector as shown in figures 8.13 &
14 and table 8.7.
Figure 8.13 Interconnect Header Connector
Figure 8.14 Interconnect PEU Connector
Compo
nent
Description
Perkins Part
Number
Supplier Part Number
Quantity
3 way plug header
connector
TBD AMP 776429-1 1
3 way Socket PEU
connector
TBD AMP 776430-1 1
18AWG Pins 2900A021 Deutsch 0460-202-1631 3
18AWG Sockets 2900A016 Deutsch 0462-201-1631 3
Table 8.7 Header to PEU Interconnect Connectors
Figure 8.15 Interconnect Harness Schematic
3-way Header Connector3-way PEU Connector
1
LEVEL
2
GND
3
TEMP
Header Connection
230-4013
1
LEVEL
2
GND
3
TEMP
PEU Connection
230-4014