Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 96
Com
ponent
Description
Perkins
Part Number
Supplier Part Number
Quantity
12-way 18-14AWG
Connector
TBD AMP 776437-1 1
Terminal Socket 2900A016 AMP 0462-201-1631 9
Sealing Plug 2900A011 AMP 114017 3
Table 8.4 PETU Communications Connector Part Numbers
8.2.2.3 Heated Line Connections
Heated DEF lines are required as standard to help prevent the fluid within the
lines from freezing during engine operation. The DEF lines are available in a
number of lengths as shown in table 8.5 The number of heated lines requiring
connection by the customer is dependent upon whether a remote PEU is
required. The heated lines are also voltage dependent and so must be
chosen to suit the overall system voltage (12 or 24V).
Line Length m
Operating Voltage
Pressurised Line (Pump to DEF Injector)
1.5
24V
2.0
2.5
3.0
3.5
4.0
4.5
5.5 (6.5m also available)
1.5
12V
2.0
2.5
3.0
Suction & Return Lines (Remote PEU Only)
1.0
24V 1.5
2.5
1.0
12V 1.5
2.0
Table 8.5 Heated Line length options
26
J1939 CAN A -
5
DCU POWER RELAY +
15
DCU POWER RELAY -
2
KEYSWITCH (DCU) HS
Engine ECM J1 Connector
1
UREA DOSING HS
2
UREA DOSING LS
3
J1939 CAN C +
4
J1939 CAN C -
5
KEYSWITCH (DCU)
6
PETU Connection
7
J1939 CAN A +
8
J1939 CAN A -
9
10
11
DCU POWER RELAY +
12
DCU POWER RELAY -
1
SUPPLY
2
RETURN
DEF Injector
25
J1939 CAN A +
3
KEYSWITCH (DCU) LS
17
J1939 CAN C +
18
J1939 CAN C -
120Ohm
120Ohm
120Ohm