the IG CEM there is also a requirement for the customer to install some
emission critical hardware. More details are given in the following section.
8.1.2 IG CEM Electrical Connections
The IG CEM aftertreatment systems are supplied directly from the factory with
all components shown in figure 8.2. Some components are supplied fitted to
the aftertreatment system whilst others must be fitted by the customer. The
table below provides an overview for the mounting requirements of each
sensor. For further information regarding the specific installation criteria for
each component please refer to section 9.
Component
On IG CEM
Additional Requirements
DPF Soot Sensor Antenna Yes Control Box must be fitted on
Machine by OEM
Engine Out NOx
Sensor
No Sensor must be fitted and wired
back to ECM J1 Connector by
OEM
DEF Injector Yes Must we wired back to Bosch
DCU.
Tailpipe Out NOx
Sensor
No Sensor must be fitted and wired
back to ECM J1 Connector by
OEM
IG CEM ID Module Yes Wiring back to ECM J1
provided by customer
Combined DPF &
SCR Inlet Temp
Yes Wiring back to ECM J1
provided by customer
Table 8.2 CEM Component Mounting Position
DPF RF Soot Sensor
Tailpipe Out Nox Sensor
Turbo Out Nox Sensor
IG CEM ID Module
DPF & SCR Inlet
Temperature Sensor
Engine ECM J1 Customer
Connector
Connector – AMP 776433-3
Sockets – Deutsch 0462-201-1631
Connector – AMP 776433-2
Sockets – Deutsch 0462-201-1631
Connector – AMP 776433-1
Sockets – Deutsch 0462-201-1631
Connector – AMP 776433-3
Sockets – Deutsch 0462-201-1631
Connector – AMP 776487-2
Sockets – Deutsch 0462-201-1631
Connector – Deutsch DRCP28-86SA
Sockets 18-16AWG – Deutsch 1062-20-0377
Sockets 12-14AWG – Deutsch 1062-12-0166