Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 79
Flying Lead is 300mm long
Figure 7.6 Tenneco XNOx DCU and Pump Unit With Factory Supplied Harness
Connection to the 31 pin customer interface connector is made using one of
the two part numbers listed below in table 7.6. The choice of which will be
dependent upon the wire gauge diameter used.
Figure 7.7 Tenneco XNOx DCU & Pump Unit 31 Pin Interface Connector
Component
Description
Perkins
Part
Number
S
upplier
Part Number
Quantity
31-way Receptacle
(reverse mount) with
sockets std Wire
diameter 2.23 –
3.4mm
TBD Deutsch HDP24-24-31ST 1
31-way Receptacle
(reverse mount) with
sockets Wire diameter
2.23 – 2.69mm
TBD Deutsch HDP24-24-31SE N/A
Sockets 2900A016 Deutsch 0462-201-1631 24
Sealing Plug 2900A011 Deutsch 114017 7
Table 7.6 Tenneco XNOx DCU & Pump Unit Connector Part Number