Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 68
Fuse (See
Note A)
Figure 6.6 ELP Installation Schematic
Note A: The lift pump supply cables and the associated fuse rating will be
dependent upon the overall system voltage. Table 6.6 gives details of the
max continuous current rating for each pump. The fuse rating selected should
be specified to protect the cable size used.
Note: For more information regarding mechanical installation and
mounting please refer to the Mechanical A&I Manual.
6.3.3.2 1206F Electric Lift Pump Installation
The 1206F product range is supplied with an engine harness connection point
for the electrical connection of the electric lift pump. The engine harness
connector is a 2 way connector that provides direct control of the lift pump via
the ECM J2 connector. It should also be noted that for those engines built
with on engine lift pump options the electrical connection to the ECM J2
connector is supplied.
All Off engine electrical lift pump options will require the 2 way connector part
number shown in table 6.8. Connection of the should be made as shown
below.
Description
Perkins
Part
Number
Supplier Part Number
Qty
Engine Harness 2
way receptacle kit
TBD N/A 1
2 way receptacle TBD Deutsch DT04-2P-E005 N/A
2 way receptacle
Wedge Lock
TBD W2P-P004 N/A
Fuel Pump 2 way
connector kit
28170051 N/A 1
2 way Plug N/A Deutsch DT06-2S-EP06 N/A
2 Way Plug Wedge
Lock
N/A Deutsch W2S-P012 N/A
14AWG Sockets 28170024 Deutsch 0462-209-1631 2
14AWG Pins 28170023 Deutsch 0460-215-1631 2
Table 6.8 Electric Lift Pump Connector Part Numbers