Once all terminals are correctly inserted into the connector body replace the
TPA taking care to ensure that correct alignment of the terminals is
maintained. Do not use excessive force when reinstalling the TPA.
Figure 5.7 TPA Fitment
Once The TPA is installed over the connector terminals the TPA will be locked
into place by the two locking tabs as shown in figure 5.7
5.3.2 Connector Disassembly
To disassemble the ECM connector the TPA must be removed as shown in
section 3.3.1. Once the TPA has been successfully removed the connector
terminals will be exposed.
To remove terminals from the connector body the Perkins removal tool 147-
6456 must be used to pull to contact retention finger away from the contact.
The wire can then be removed by gently pulling the wire from the back of the
connector as shown in figure 5.8
Figure 5.8 Wire Removal
TPA Locking tab
Pull the contact retention finger away from the
contact