Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 54
Figure 5.5 TPA Removal Tools
Once the TPA is removed the connector can be populated with the required
terminal population.
To insert the sockets into the connector push the wire through from the back
of the connector until the locking tab clicks into place.
Figure 5.6 Correct Pin Location
Warning: When populating the ECM connector start by inserting cables into
the centre of the connector body (near to the jack screw) to prevent the
connector seal from becoming compressed and interfering with the wire
installation.
Warning: If stamped and formed terminals are used, ensure that the terminal
is not bent before insertion. A bent terminal may not properly lock into
position.
Miss aligned socket
Open latch, socket will get
push out when installing
the TPA