Installation Manual

Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 50
Figure 5.2 ECM J1 Dress Cover
5.1.7 Machine Crimping For High Volume Production
For high volume and automated crimping solutions please contact the supplier
directly for tooling details.
5.2 Engine ECM J1 Connector I/O
Pin
Position
ECM Driver
Function
Contact
Size
1 3.75A PWM Driver LS3 Reserved 18AWG
2 3.75A PWM Driver HS2 Keyswitch (DCU) HS 18AWG
3 3.75A PWM Driver LS2 Keyswitch (DCU) LS 18AWG
4 2.5A PWM Driver HS1 Hydraulic Demand Fan Solenoid
+
18AWG
5 2A PWM Sourcing 1 DCU Power Relay + 18AWG
6 2A PWM Sourcing 2 Reserved 18AWG
7 2A On/Off Sourcing 1 Engine Fuel Lift Pump 18AWG
8 2A On/Off Sourcing 2 Glow Plugs 18AWG
9 2A On/Off Sourcing 3 Ether start 18AWG
10 3.75A PWM Driver HS3 Reserved 18AWG
11 Fan I/P 1 Fan Speed Sensor (HE) 18AWG
12 2.5A PWM Driver LS1 Hydraulic Demand Fan Solenoid - 18AWG
13 CAN D+ Machine Specific Data Link 18AWG
14 Sourcing Return 3.75A On/Off Sourcing Return 18AWG
15 Sourcing Return 2A PWM Sourcing Return 18AWG
16 300mA Sinking 1 Wait To Start Lamp 18AWG
17 CAN C+ DEF Pump, Soot, NOx(EO), NOx
(TO), Def-Q
18AWG
18 CAN C- DEF Pump, Soot, NOx(EO), NOx
(TO), Def-Q
18AWG
19 CAN C Shield CAN C Shield 18AWG
20 CDL+ CDL + 18AWG
21 CAN D- Machine Specific Data Link 18AWG
22 CAN D Shield Machine Specific Data Link 18AWG
23 300mA Sinking 3 Oil Pressure Lamp 18AWG
24 300mA Sinking 2 Wait To Disconnect Indicator 18AWG
25 CAN A+ Application Data Link 18AWG
26 CAN A- Application Data Link 18AWG
27 CAN A Shield Application Data Link 18AWG
28 CDL- CDL - 18AWG
29 Analogue Return Passive analogue Return 18AWG