Table 4.6 Typical AWG Conductor Resistance / m
Figure 4.3 ECM Supply Circuit
As with all electrical circuits wire should be selected so that the rated
maximum conductor temperature is not exceeded for any combination of
electrical loading, ambient temperature, heating effects of bundled cables,
protective braid, conduit and other enclosures. Consult wire manufacturers
data sheets for further information.
2m
4m
6m
8m
10m
14 Ni-plated Copper 9.82 19.64 39.28 58.92 78.56 98.2
12 Ni-plated Copper 6.41 12.82 25.64 38.46 51.28 64.1
10 Ni-plated Copper 4.11 8.22 16.44 24.66 32.88 41.1
8 Ni-plated Copper 2.59 5.18 10.36 15.54 20.72 25.9
6 Ni-plated Copper 1.55 3.1 6.2 9.3 12.4 15.5
4 Ni-plated Copper 1.06 2.12 4.24 6.36 8.48 10.6
2 Ni-plated Copper 0.62 1.24 2.48 3.72 4.96 6.2
0 Ni-plated Copper 0.383 0.766 1.532 2.298 3.064 3.83
00 Ni-plated Copper 0.27 0.54 1.08 1.62 2.16 2.7
000 Ni-plated Copper 0.204 0.408 0.816 1.224 1.632 2.04
0000 Ni-plated Copper 0.159 0.318 0.636 0.954 1.272 1.59
American
Wire Gauge
Material
mohm/m at
20Deg C
mOhm at 20Deg C for Cable Length
A5E2 ECM
-
+
Battery
Negative Wire Resistance
(Ohms)
Positive Wire Resistance
(Ohms)
Circuit Load (ECM)
Total Circuit Length
Note: Circuit protection not shown