Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 205
Note: Do not splice the sensor signal wire for input to third party
devices.
Figure 15.7 Auxiliary Temperature Sensor T400032
REQUIRED PARTS
Perkins
Part
Number
Supplier Part Number
Description
Qt
y
T400032 N/A Temperature Sensor
(Auxiliary)
1
2900A013 N/A Connector Plug Kit 1
N/A Deutsch DT06-2S-EP06
Connector Plug 1
N/A Deutsch W2S-P012 Wedge Lock 1
2900A016 Deutsch 0462-201-1631
Connector Socket
(Gold)
2
Table 15.10 Auxiliary Temperature Sensor Installation Parts List
The following harness design and routing guidelines are recommended for
best accuracy of passive analogue devices:
•
Use of gold sockets is strongly recommended.
•
Sensor wires should be shielded or they should be routed in a separate
harness bundle from switching currents that are greater than 100mA.
•
Maximum allowable wire length from the ECM to the sensor is 3.65m
(12ft).
•
Preferred wire gauge is 18AWG (1.0mm²).
•
The maximum allowable number of connector junctions is two.
As this sensor incorporates a pigtail harness the following installation
instructions must also be observed:
The connector interface should never be tied directly to a vibrating member.
The pigtail wire lead should be tied down on only one side of the connector
interface. It is recommended that one of the following locations are selected,
midpoint on the sensor pigtail or 150mm from the connector on the harness
side.
The Auxiliary temperature sensor is a 2 wire sensor and figure 15.8 shows the
wiring required to connect the sensor to the engine ECM J1 connector.
Figure 15.8 Auxiliary Temperature Sensor Installation Wiring