Installation Manual

Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 194
14.3.2.1 DEF Quality, Tampering & Dosing Interruption
Normal
Operation
Level 1 Level 2 Level 3 Safe Harbor
Inducement
Time 1
st
Occurrence
Until Fault 2.5hrs 70mins Until Fault Heals
20mins
Initiated by
first key
cycle after
Level 3
Inducement
Time Repeat
Occurrence
Until Fault 5mins 5mins Until Fault Heals 20mins
Initiated by
first key
cycle after
Level 3
Inducement None None None 5 minute Cool
down with 100%
Torque derate
Then
Shutdown or
Idle Only
None
Notification None
Emissions
System
Failure
Lamp
+
Engine
Shutdown Lamp
14.3.2.2 Impeded EGR
Normal
Operation
Level 1 Level 2 Level 3 Safe Harbor
Inducement
Time 1
st
Occurrence
Until Fault 35hrs 60mins Until Fault Heals 20mins
Initiated by
first key
cycle after
Level 3
Inducement
Time Repeat
Occurrence
Until Fault 48mins 60mins Until Fault Heals 20mins
Initiated by
first key
cycle after
Level 3
Inducement None None None 5 minute Cool
down with 100%
Torque derate
Then
Shutdown or
Idle Only
None