14.2.5 High NRS Temperature
14.2.5.1 High NRS Temperature Operation
The engine control system monitors the NRS gas temperature in order to
prevent the temperature exceeding allowable levels. This monitoring system
parameter is required to prevent component damage due to excessive NRS
temps. The High NRS temperature protection supports Severity L1 and
Severity L2 only. When an L2 event is triggered the engine will initiate a
derate as shown in table 14.13. The associated diagnostics are shown below.
Parameter
Temp °C
De
-
rate %
Severity L1 178 0
Severity L2 180 0
181 30
182 35
183 40
184 50
Table 14.13 High NRS Temperature Monitoring Mode Derate Operation
Service
Tool Description
J1939
Description
Status
SPN
(J1939)
FMI
(J1939)
Event
Code
Engine
Action (If
Enabled)
High Exhaust
Temperature
High NRS
Temperature
Severity L1 412 15 E1092-1 Warning Lamp
Only
Severity L2 412 16 E1092-3 Engine Derate
Table 14.13 High EGR Temperature Monitoring
14.2.5.2 High NRS Temperature Configuration
The High NRS Temperature monitoring mode is a factory set monitoring
mode, which has fixed thresholds that, cannot be adjusted.
14.2.5.3 High NRS Temperature Installation