14.2.2.3 Engine Oil Pressure Monitoring Mode Installation
No installation is required for the engine oil pressure monitoring function.
14.2.3 Intake Manifold Temperature
14.2.3.1 Intake Manifold Temperature Monitoring Mode Operation
The engine intake manifold air temperature is monitored by the engine
management system to ensure that the engine remains emissions compliant
when high intake manifold temperatures are measured. The values shown
below are factory set values, where the max temperature is set to 129°C.
This value is non-configurable.
Parameter
Temp °C
De
-
rate %
Severity L1 123 0
Severity L2 125 0
126 20
127 30
128 40
129 50
Table 14.8 Intake Manifold Temperature Monitoring Mode Derate Operation
Once the engine ECM detects that the engine intake manifold air temperature
has exceeded one or more of the defined threshold limits a corresponding
event code is raised as shown below.
Service
Tool Description
J1939
Description
Status
SPN
(J1939)
FMI
(J1939)
Event
Code
Engine
Action (If
Enabled)
High Intake
Manifold Air
Temperature
Intake Manifold
Air Temperature
Severity L1 105 15 E539-1 Warning Lamp
Only
Severity L2 105 16 E539-3 Engine
Shutdown
Table 14.9 Intake Manifold Temperature Monitoring
14.2.3.2 Intake Manifold Temperature Monitoring Mode Configuration
Using the Perkins EST service tool the following parameters can be
configured.
The Maximum Intake manifold temperature limit is set within the ECM
software and cannot be adjusted however the trigger points for severity L1
and severity L2 functions can be configured below this value within the
following range shown below.
Engine Range
Monitoring Mode
Level
Trip Threshold Min
Trip Threshold Max
All Severity L1 100°C 123°C
All Severity L2 100°C 125°C
Table 14.10 Intake Manifold Temperature Monitoring Mode Configuration
14.2.3.3 Intake Manifold Temperature Monitoring Mode Installation
No installation is required for the engine intake manifold temperature
monitoring function.