Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 182
Function
PGN
SPN / Byte
Start bit
Length
Applicabl
e
States
Low DEF Level
Indicator
FE56 5245 / 5 6 3 000 (OFF)
001 (ON)
13.3.10 Wait To Disconnect Indicator
13.3.10.1 Wait To Disconnect Indicator Operation
The wait to disconnect Indicator is a mandatory fit item used to alert the
machine operator that the Engine & DEF system are still active and the
battery isolation switch should not be used. Post ignition off, the DEF system
must perform a fluid purge cycle that requires the use of the DEF pump motor.
If system power is removed during the purge cycle the fluid left within the
pumps and the DEF lines may cause component failures. Further information
regarding the purge operation is shown in section 16 of this document.
13.3.10.2 Wait To Disconnect Indicator Configuration
No configuration is required to enable the Wait To Disconnect Indicator.
13.3.10.3 Wait To Disconnect Indicator Installation
1204F
Function
PGN
SPN / Byte
Start bit
Length
Applicable States
Wait To
Disconnect
Indicator
61475 4332 3.1 4bits ON = any state other than
1011
OFF = 1011 System
Shutoff
1206F
Function
PGN
SPN / Byte
Start bit
Length
Applicable States
Wait To
Disconnect
Indicator
61475 4332 3.1 4bits ON = any state other than
0111
OFF = 0111 System
Shutoff
13.3.11 Delayed Engine Shutdown Active Indicator (1206F Only)
13.3.11.1 DES Indicator Operation
For all machines using the Delayed Engine Shutdown feature provided by the
engine ECM there is a requirement for the machine manufacturer to
communicate the DES Active state to the operator. During a DES event the
engine rpm will remain at the programmed Low idle speed post ignition key