Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 178
N/A Wait To
Disconnect
Indicator
Wait To
Disconnect
Used to indicate
that the engine
and DEF system
are active.
N/A
*
Indicator required for all 1206F engines configured with Delayed Engine
Shutdown Active. More details in section 16.3.1.
13.3.4 Engine Shutdown Indicator
13.3.4.1 Engine Shutdown Indicator Operation
The engine shutdown indicator is operated upon the engine entering an
operating / fault condition which requires the engine to shut down for control /
safety reasons. If the engine monitoring system is configured to a level 3
(warn, de-rate and shutdown) then the engine may also automatically shut
down. The engine shutdown lamp is also used to in conjunction with the
Emissions system malfunction indicator to signal emissions critical faults.
13.3.4.2 Engine Shutdown Indicator configuration
The engine shutdown indicator is a mandatory fit item. There is no
configuration necessary for the Engine shutdown indicator.
13.3.4.3 Engine Shutdown Indicator Installation
The Engine shutdown Indicator is also available via J1939 as shown below.
Function
PGN
SPN / Byte
Start bit
Length
Applicable
States
Shutdown
Indicator status
FECA 623 / 1 5 2 00 (OFF)
01 (ON)
Shutdown
Indicator Flash
FECA 3039 / 2 5 2 11 (Do Not
Flash)
13.3.5 Engine Warning Indicator