Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 176
To support new standards and requirements, Perkins may add to the fault
code table. Therefore, any active engine fault codes including those not
recognized or referenced should be displayed.
13.3 Lamp Outputs & Operation
13.3.1 Hardwired Lamp Outputs
All mandatory engine and aftertreatment indicators are provided as standard
as dedicated ECM outputs. Engine ECM pin allocation for each of these
indicators is shown below in table 13.2
Indicator Description
Mandatory Fit Engine
Family
Pin Allocations ECM J1
Warning Indicator All 31
Shutdown Indicator All 32
Engine Wait To Start
Indicator
All 16
Oil Pressure Indicator Optional 23
Emissions System
Malfunction Indicator
All 40
Low DEF Level Indicator All 39
Wait To Disconnect Indicator Recommended All 24
Delayed Engine Shutdown
Active
Optional 1206F 48
Table 13.2 Hardwired Indicator ECM Location
13.3.2 J1939 Indicator Support
All hardwired status indicators are supported as J1939 messages to support
those customers wishing to incorporate these signals into a machine display.
PGN and SPN support for these parameters are shown below.
Indicator Description
PGN
SPN
Warning Indicator FECA (65226) 642
Warning Indicator Flash FECA (65226) 3040
Shutdown Indicator FECA (65226) 623
Engine Protect Indicator FECA (65226) 987
Engine Protect Indicator
Flash
FECA (65226) 3041
Engine Wait To Start
Indicator
FEE4 (65252) 1081
Oil Pressure Indicator N/A N/A
Emissions System
Malfunction Indicator
FECA (65226) 1213
Emissions System
Malfunction Indicator Flash
FECA (65226) 3038
Low DEF Level Indicator (65110) (5245)
Wait To Disconnect Indicator F023 (61475) 4332
Delayed Engine Shutdown
Active
FD92 (64914) 3543
Table 13.3 J1939 Indicator Support