Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 121
• Further fixation points maybe required depending on cable routing.
• All excess cable length must be secured to the machine body to
prevent damage by friction / abrasion with surrounding components.
Connection to each inlet temperature sensor is made using a 2 pin Ampseal
connector as shown in figure 9.29 and table 9.18 Each specific sensor
terminal assignments are shown in table 9.19.
Figure 9.29 DOC, DPF & SCR Temp Sensor Electrical Connector
Component
Description
Perkins
Part
Number
Supplier Part Numbe
r
Quantity
2-way Connector Plug TBD AMP 282080-1 1
Connector Sockets
18AWG
TBD
AMP 282110-1 2
Wire Seal (18AWG)
Wire Dia 1.8 – 2.4mm
TBD
AMP 281934-2 2
Table 9.18 DOC, DPF & SCR Temp Sensor Connector Detail
DOC Inlet Temperature Sensor
Pin
Location
De
scription
Terminal Socket P/N
1 XRDG (0V) 282110-1
2 DOC Inlet Temperature Sensor 282110-1
DPF Inlet Temperature sensor
Pin
Location
Description
Terminal Socket P/N
1 XRDG (0V) 282110-1
2 DPF Inlet Temperature Sensor 282110-1
SCR Inlet Temperature Sensor
Pin
Location
Description
Terminal Socket P/N
1 XRDG (0V) 282110-1
2 SCR Inlet Temperature Sensor 282110-1
Table 9.19 DOC, DPF & SCR Temp Sensor Terminal Assignment