Installation Manual

Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 118
Figure 9.24 DOC, DPF & SCR ID Module Transit Mounting Location
9.5.3.3 1206F DOC, DPF & SCR ID Module Mounting
The module is supplied attached to a sensor mounting plate, which forms part
of the overall aftertreatment system. No ID module installation is required by
the OEM. The OEM is responsible however for connecting the DPF ID
module to the engine ECM J1 connector as part of the machine wiring
harness.
9.5.3.4 ID Module Electrical Connection and Wiring
Connection to the Aftertreatment ID module is made via a 6 way plug as
shown in figure 9.25 and table 9.16. Figure 9.26 also shows the wiring
schematic for connection of the module back to the engine ECM.
Figure 9.25 IG CEM ID Module 6 Way Connector
Component
Description
Perkins
Part Number
Supplier Part Number
Quantity
6-way Connector Plug TBD AMP 776433-3 1
Connector Sockets
18AWG
2900A016 Deutsch 0462-201-1631 3
Blanking Plug 2900A011 Deutsch 114017 3
Table 9.16 CEM ID Module Connector Detail