Installation Manual
Electrical & Electronic Application And Installation Manual
Production Release Version 1.0
Page 108
• Harness must be secured every 6” or 150mm or less.
• Bend radius of the harness must be >=20mm.
Good Cable Support Example
Figure 9.7 NOx sensor Cable Support
Bad Cable Support Example
Harness Not support and exit from
rear of sensor >15Deg
Figure 9.8 Improper NOx Sensor Cable Support
For machines where relative motion between the first harness clipping point
and the rear of the sensor a security loop needs to be used as shown below.
The loop needs to be implemented in such a way as to ensure that movement
of the exhaust pipe during vehicle operation will not tighten and damage the
harness. The length of the security loop should be adapted to suit the
application to meet the amplitude of exhaust pipe movement.