Troubleshooting

68 RENR2696-01
Troubleshooting Section
The ECM has been powered for at least fifteen
seconds.
CID 262-03 5V Sensor Power Supply Voltage More
Than Normal an
d CID 262-04 5V Sensor Power
Supply Voltage Less Than Normal are not active.
System Respon
se:
The ECM will set the intake manifold pressure to a
default value
.
The electronic service tool will display “Open/Short
High” for the
intake manifold pressure on the status
screen.
The ECM will g
enerate a CID 102 FMI 03 diagnostic
code on the Data Link. The diagnostic code will be
displayed on a d iagnostic screen of the electronic
service tool
.
Possible Performance Effect:
Theenginecouldhavelowpowerwhilethediagnostic
code is active.
Perform the following diagnostic procedure: “Engine
Pressure Sensor Open or Short Circuit - Test”
Results:
OK STOP.
i01798149
CID 0102 FMI
04 Intake
Manifold Pressure Sensor
Shorted Low
Condition
s Which Generate This Code:
The Electronic Control Module (ECM) detects all of
the follow
ing conditions:
The ECM detects a signal voltage that is below
normal.
The ECM has been powered for at least fifteen
seconds.
CID 262-03 5V Sensor Power Supply, Voltage
More Than
Normal and CID 262-04 5V Sensor
Power Supply, Voltage Less Than Normal are not
active.
System Response:
The ECM will set intake manifold pressure to a
default value.
The electronic service tool will display “Short to
Ground” for the intake manifold pressure on the
status screen
.
The ECM will generate a CID 102 FMI 04 diagnostic
code on the Dat
aLink.Thediagnosticcodewillbe
displayed on a diagnostic screen of the electronic
service tool.
Possible Pe rformance Effect:
The engine co
uld have low power while the diagnostic
code is active.
Perform the f
ollowing diagnostic procedure: “Engine
Pressure Sensor Open or Short Circuit - Test”
Results:
OK STOP.
i01877642
CID 0102 FMI 10 Intake
Manifold Pr
essure Sensor
Power Sup ply Open Circuit
Conditions Which G enerate This Code:
If the 5 volt connection to the sensor is an open
circuit, this fault will result in a logged code.
The Electronic Control Module (ECM) detects all of
the following conditions:
No other CID 0262 or CID 0102 codes are active.
The engine s
peed is greater than 600 rpm.
The pressure sensor signal from the intake
manifold i
s within the expected range for this failure
mode.
The pressu
re sensor signal from the intake
manifold remains abnormally constant because the
variations in the sensor signal are too small.
All of the above conditions occur simultaneously
for a period of 30 seconds.