Troubleshooting

188 RENR2696-01
Troubleshooting Section
F. Check that there is no voltage with the keyswitch
in the OFF posit
ion.
Expected Result:
The measured voltage is between 11.0 VDC and 13.5
VDC for a 12 volt system and between 22.0 VDC and
27.0 VDC for a 2
4 volt system with no suspected
intermittent problems at this time.
Results:
OK
Repair: There is a problem with the relay. Replace
the relay and verify that the repair has eliminated
the problem.
STOP.
Not OK There is no voltage or the voltage is out
of the acceptable range. Proceed to Test Step 8.