Warranty

PERGO Outlast+ Limited Lifetime Residential Warranty
All areas must be assessed prior to installation of flooring to determine if other surface
measures need to be taken or conditions addressed, including, but not limited to
requirements for static control, state health and building codes, slip resistance, high
impact trac and moisture/water exposure. Other than the specific warranty identified
above, Pergo provides no additional warranties and Pergo does not warrant that any
of the uses identified above are in compliance with any applicable building, health,
inspection, and/or other municipal regulation or codes. Pergo is not responsible for usage
that is not in compliance with any regulation or code. Proper assessment of location and
usage must be applied. Contact your Pergo representative for questions on performance
in specific locations.
The Pergo Outlast+ Limited Lifetime Residential Warranty and Limited 10-Year Light
Commercial Warranty are made subject to the following conditions:
1. The floor must be installed properly in accordance with Pergo installation instructions.
The instructions should be obtained through a retailer or at 1-800-33-PERGO (1-800-
337-3746) or www.pergo.com. Proper installation includes, but is not limited to, the
following:
A moisture test must be performed to determine if excessive moisture exists in the
subfloor.
When using a calcium chloride moisture test for concrete subfloors (ASTM F1869),
values must be 5 lbs/1000ft
2
/24-hr or <80% RH with an in-situ probe (ASTM
F2170).
A polyethylene film vapor barrier is not required over wood subfloors. Moisture
readings of wood subfloors must be 12% throughout the entire installation.
For planks without attached underlayment, install over a single layer of
underlayment appropriate for laminate floors.
For planks with attached underlayment, it is acceptable to install Pergo FloorMate™
underlayment prior to flooring installation if desired. Make sure to follow the Pergo
FloorMate™ installation instructions, taking special care to seal all foam edges
with sealing tape and repair all rips and perforations in the underlayment vapor
barrier prior to flooring installation. A separate vapor barrier should not be used in
conjunction with Pergo FloorMate™.
The entire perimeter of the installation must be sealed with 100% silicone sealant.
All expansion spaces must be filled with 3/8” compressible PE foam backer rod and
covered with 100% silicone sealant. Apply 100% silicone sealant to all moldings
at the point of contact with the flooring surface. Apply silicone sealant at all
connections to doorframes or any other fixed objects.
When installing Pergo in special situation areas such as: terrazzo, pier and beam,
radiant heating and to also learn how to properly acclimate your floor, please
contact our consumer help line at 1-800-33-PERGO (1-800-337-3746) or log on to
www.pergo.com to obtain important additional information.
Failure to fully engage the locking system around all sides of each plank during
installation could result in gaps that will void this limited warranty.
2. The flooring must be used only indoors in a dry, climate-controlled area.
3. The flooring must be maintained in accordance with Pergo care and maintenance
2020_06_OP_WAR