Instructions / Assembly

3
CONTROL PADS ON THE DEHUMIDIFIER
NOTE: The control panel of the unit you purchased may be slightly dierent according to the models.
High Fan
Indicator Light
Clean Filter
Indicator Light
Filter
Comfort
Full
Cont. On Off
Turbo
Auto defrost
Power
Continuous
Operation on
Indicator Light
Timer “On”
Indicator Light
Timer “Off
Indicator Light
Auto Defrost
Operation
Indicator Light
Bucket Full
Indicator Light
Comfort
Dehumidifying
Indicator Light
Timer
Mode
8
4
12
3
765
CONTROL PADS: When you push the button to change
operation modes, the unit will make a single “beep”
sound to indicate that it is changing modes.
1. POWER
Press to turn the dehumidier on and o.
2. MODE
Toggle between the following features:
NORMAL Utilize this mode if you would like the
unit to cycle on and o based on the relative
humidity setting you have manually selected. (See
numbers 5, 7 and 8 in the column to the right for
further instruction.) In NORMAL mode, both the
“Comfort” and “Cont.” indicator lights will not be
illuminated.
COMFORT Utilize this dehumidication feature
to automatically keep humidity in the 45%-
55% range based on room temperature. When
operating in this mode the UP/DOWN
/ pads
will be deactivated and you will NOT be able to set
a desired humidity.
CONTINUOUS (CONT.) Press to activate the
continuous dehumidifying operation. When
operating in this mode the UP/DOWN
/ pads
will be deactivated and you will NOT be able to
set a desired humidity. The unit will run non-stop
unless using the bucket to collect water. At which
point, the unit will shut o when the bucket is full.
3. FILTER
The check lter feature is a reminder to clean the
Air Filter for more ecient operation. The “Filter”
light (Clean Filter Indicator Light) will illuminate
after 250 hours of operation. To reset after
cleaning the lter, press and hold the Filter button
and the light will go o, resetting the timer.
4. FAN
Control the fan speed. Press to select either Turbo
or Normal fan speed. Set the fan control to Turbo
(“High”) for maximum moisture removal. When the
humidity has been reduced and quiet operation
is preferred, set the fan control to Normal by
pressing the FAN pad to turn o Turbo fan/light.
5/7.
/ : UP/DOWN PADS
HUMIDITY SET CONTROL PADS
The humidity level can be set within a range
of 35%RH to 85%RH (Relative Humidity) in
5% increments.
For drier air, press the
pad and set to a lower
percent value (%).
For damper air, press the
pad and set a higher
percent value (%).
The recommended standard setting is 45-50%.
You must be on Normal mode to set the humidity
Cannot be used in COMFORT or
CONTINUOUS mode.
6. TIMER
Press to initiate the Auto on and Auto o feature,
in conjunction with the
and key pads. The
timer range is 0.0 to 24 hrs. Timer does not cycle.
8. DISPLAY
Shows the set % humidity level from 35% to 85%
or auto on/o time (0-24) while setting, then
shows the actual ( +/- 5% accuracy) room %
humidity level in a range of 30%RH to 90%RH
(Relative Humidity).