Operation Manual

AC06
V. 03 22/02/2016 5 ©Velleman nv
down/stabilize for about 10 minutes before re-connecting to the mains. If after several hours the
charger still doesn’t indicate that the battery is being charged, a short-circuited element might be
present inside the battery. The battery must be replaced.
The charging procedure is finished when the green LED [C] lights up. Note that the intensity of the
green LED [C] gradually builds up.
The battery charger doesn’t stop automatically. When the green LED [C] shines bright, disconnect
the charger from the mains.
Disconnect the battery from the charger, starting with the clamp on the negative pole (black) and
than proceed with the clamp on the positive pole (red).
When the fuse [D] is blown, the fuse will light. Replace the fuse in the front of the charger by a fuse
with the same specifications. Make sure no battery is connected to the charger and the charger is
disconnected from the mains when replacing the fuse. Use a small screwdriver as a lever to release
the fuse from its socket. Insert the new fuse. Avoid the use of excessive force!
8. Cleaning and Maintenance
Always remove the plug from the mains socket and disconnect batteries when servicing or cleaning
the charger.
Never use water or any other liquids to clean the charger.
Keep the cables clean, but avoid using cleaners based on benzene, trichloroethylene, chloride,
ammonia … as they affect or even dissolve plastic parts.
Check liquid level of batteries once per month and fill up when necessary.
Dispose of batteries in accordance with local regulations.
9. Technical Specifications
rated input voltage ............................................................................. 230 V~, 50 Hz
rated output current ....................................................................................... 4.5 A
effective charging current .................................................................................. 6 A
exchangeable fuse .......................................................................................... 20 A
reference battery capacity .......................................................................... 20-90 Ah
IP-code .......................................................................................................... IP20
weight ........................................................................................................... 3 kg
dimensions .............................................................................. 230 x 175 x 115 mm
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.perel.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.