Users Manual

https://www.peplink.com 133 Copyright @ 2019 Peplink
In the diagram, the WAN ports of each Peplink Balance unit connect to the router and to the modem. Both
Peplink Balance units connect to the same LAN switch via a LAN port.
An elaboration on the technical details of the implementation of virtual router redundancy protocol (VRRP,
RFC 3768) by the Balance follows:
In an HA configuration, the two Peplink Balance units communicate with each other using VRRP
over the LAN.
The two Peplink Balance units broadcast heartbeat signals to the LAN at a frequency of one
heartbeat signal per second.
In the event that no heartbeat signal from the master Peplink Balance unit is received in 3
seconds (or longer) since the last heartbeat signal, the slave Peplink Balance unit becomes
active.
The slave Peplink Balance unit initiates the WAN connections and binds to a previously
configured LAN IP address.
At a subsequent point when the master Peplink Balance unit recovers, it will once again become
active.
You can configure high availability at Network>Misc. Settings>High Availability.
Interface for Master Router Interface for Slave Router