Datasheet

Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Diffuse mode sensor
VT18-8-400-M/40a/118/128
4
Release date: 2018-07-27 11:39 Date of issue: 2018-07-27 801132_eng.xml
Sensitivity adjustment
Turn sensitivity adjuster (counterclockwise) to minimum position.
Place the object to be detected in the sensing range and turn the sensitivity adjuster
clockwise until the yellow indication LED lights up. This setting indicates the position A
of the sensitivity adjuster.
Remove the object. Increase the sensitivity slowly (turning the sensitivity adjuster
clockwise) until the yellow LED lights up again. This setting indicates the position B of
the sensitivity adjuster.
Note:
In case of no background object, the LED won’t light up, even in MAX. adjustment. In
that case take care, that in normal operation conditions no temporal background object
can appear in the sensing range (e. g. parked pallets). If this can not be excluded,
place (only for adjustment matter) an object at the appropriate location. Then repeat
this adjustment step. After finishing the adjustment this temporal object should be
removed.
For optimal setting, now turn the sensitivity adjuster to the middle position between the positions A and B.
sensitivity adjusterlight/dark switch
yellow LED
position A position
B
optimal setting
SENS.
DL