Datasheet

Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
1
Ultrasonic sensor UC500-30GM-IUEP-IO-V15
Release date: 2017-10-24 12:02 Date of issue: 2017-10-27 191238_eng.xml
Technical data
General specifications
Sensing range 30 ... 500 mm
Adjustment range 50 ... 500 mm
Dead band 0 ... 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 380 kHz
Response delay minimum : 25 ms
factory setting: 45 ms
Memory
Non-volatile memory EEPROM
Write cycles 100000
Indicators/operating means
LED green solid: Power on
flashing: Standby mode or IO link communication
LED yellow 1 solid: Object in evaluation range
flashing: Learning function, object detected
LED yellow 2 solid: Object in evaluation range
flashing: Learning function, object detected
LED red solid red: Error
red, flashing: program function, object not detected
Electrical specifications
Operating voltage U
B
10 ... 30 V DC , ripple 10 %
SS
15 ... 30 V voltage output
No-load supply current I
0
60 mA
Power consumption P
0
1 W
Time delay before availability t
v
100 ms
Interface
Interface type IO-Link
Protocol IO-Link V1.0
Transfer rate Acyclical: typical 240 Bit/s
Cycle time min. 13.2 ms
Mode COM 2 (38.4 kBaud)
Process data witdh 16 bit
SIO mode support yes
Input/Output
Input/output type 1 synchronization connection, bidirectional
0 Level 0 ... 1 V
1 Level 4 V ... U
B
Input impedance > 12 k
Output rated operating current < 12 mA
Pulse length 0.5 ... 300 ms (level 1)
Pulse interval 14 ms (level 0)
Synchronization frequency
Common mode operation 70 Hz
Multiplex operation 90 Hz / n , n = number of sensors , n 10
(factory setting: n = 5 )
Output
Output type 1 push-pull (4 in 1) output, short-circuit protected, reverse
polarity protected
Current output 4 mA ... 20 mA or
voltage output 0 V ... 10 V configurable
Rated operating current I
e
200 mA , short-circuit/overload protected
Voltage drop U
d
2.5 V
Resolution current output: evaluation range [mm]/3200 but 0.05 mm
voltage output: evaluation range [mm]/4000 but 0.05 mm
Deviation of the characteristic curve 0.2 % of full-scale value
Repeat accuracy 0.1 % of full-scale value
Switching frequency f 11 Hz
Range hysteresis H 1 % of the adjusted operating range (default settings),
programmable
Load impedance current output: 300 Ohm
voltage output: 1000 Ohm
Temperature influence 1.5 % from full-scale value (with temperature
compensation)
0.2 %/K (without temperature compensation)
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 5-pin
Degree of protection IP67
Material
Housing Stainless steel 1.4305 / AISI 303
TPU
Polyamides
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 66 g
Factory settings
Output 1 near switch point: 50 mm
far switch point: 500 mm
Output mode: Window mode
output behavior: NO contact
Model Number
UC500-30GM-IUEP-IO-V15
Single head system
Features
IO-link interface for service and
process data
Programmable via DTM with
PACTWARE
Switch output and analog output
Selectable sound lobe width
Synchronization options
Temperature compensation
Diagrams
200
150
100
50
0
-50
-100
-150
-200
X
Y
Characteristic response curve
Distance X [mm]
Distance Y [mm]
flat surface
100 mm x 100 mm
round bar, Ø 25 mm
wide sound lobe
narrow sound lobe
0 100 200 300 400 500 600 700 800 900 1000 1100

Summary of content (5 pages)