Datasheet

Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
1
Ultrasonic sensor UC2000-30GM70-IE2R2-V15
Release date: 2016-02-16 08:29 Date of issue: 2016-02-16 238386_eng.xml
Technical data
General specifications
Sensing range 100 ... 2000 mm
Adjustment range 150 ... 2000 mm
Dead band 0 ... 100 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 200 kHz
Response delay 100 ms
Nominal ratings
Temperature drift ± 1.5 % of full-scale value
Time delay before availability t
v
125 ms
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED yellow switching state switch output
LED green/yellow yellow: object in evaluation range
green: Teach-In
Potentiometer switch output adjustable
Electrical specifications
Rated operating voltage U
e
24 V DC
Operating voltage U
B
20 ... 30 V DC (including ripple)
Ripple 10 %
No-load supply current I
0
50 mA
Interface
Interface type Infrared
Mode point-to-point connection
Input/Output
Input/output type 1 synchronization connection, bidirectional ( Factory setting:
synchronized mode ) / Teach-In input
0 Level 3 V
1 Level 15 V
Input impedance typ. 900
Number of sensors max. 10
Switching output
Output type 1 switch output PNP, NO ( NC contact programmable )
Default setting 150 ... 2000 mm ( adjustable via potentiometer )
Repeat accuracy R ± 3 mm
Operating current I
L
300 mA , short-circuit/overload protected
Switching frequency 4 Hz
Switching hysteresis 20 mm ( programmable )
Voltage drop 3 V
Off-state current 10 µA
Analog output
Output type 1 current output 4 ... 20 mA , ascending/descending
programmable
Default setting rising ramp ; evaluation limit A1: 150 mm ; evaluation limit
A2: 2000 mm
Load resistor 500
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Shock resistance 30 g , 11 ms period
Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP65
Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Installation position any position
Mass 140 g
Construction type Cylindrical
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
IEC 60947-5-2:2007 + A1:2012
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
36 V
Model Number
UC2000-30GM70-IE2R2-V15
Ultrasonic direct detection sensor
Features
Analog output 4 ... 20 mA
•1 switch output
Synchronization options
Temperature compensation
Can be parameterized via the ULT-
RA-PROG-IR software and inter-
face (accessories)
Diagrams
1
2
X
Y
Characteristic response curve
Distance X [mm]
Distance Y [mm]
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
500
250
0
-250
-500