Datasheet
3
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
UC2000-30GM-IUR2-V15
Ultrasonic sensor
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
LED Displays/Analogue output
Note on communication with the UC-30GM-R2 interface cable
The UC-30GM-R2 interface cable allows for communication with the ultrasonic sensor using the ULTRA 2001 service program.
The cable creates a connection between the PC-internal RS 232 interface and the plug-in connection for the temperature/pro-
gram plug on the sensor. When setting up the connection on the sensor, make certain the plug is lined up correctly; otherwise
no communication will be possible. The protrusion of the round plug must be inserted into the groove of the plug connection
on the sensor side and not into the arrow symbol on the sensor.
Adjustable parameter with service program ULTRA 2001
- Evaluation limits A1 and A2
- Rising/falling ramp/zero line
- Mode of operation
-Sonic speed
- Temperature offset (The inherent temperature-rise of the sensor can be considered in the temperature compensation)
- Expansion of the unusable area (for suppression of unusable area echoes)
- Reduction of the detection range (for suppression of remote range echoes)
- Time of measuring cycle
- Acoustic power (interference of the burst duration)
- Sensitivity
- Behaviour of the sensor in case of echo loss
- Behaviour of the sensor in case of a fault
- Average formation via an allowed number of measuring cycles
- Selection of the parameter set, RS 232 or manually.
Displays in dependence on operating
mode
Dual
LED
green
Dual-
LED
red
LED
yellow A1
LED
yellow A2
analogue out-
put
TEACH-IN evaluation limit A1
object detected
object not detected
flashing
off
off
flashing
flashing
flashing
off
off
unchanged
TEACH-IN evaluation limit A2
object detected
object not detected
flashing
off
off
flashing
off
off
flashing
flashing
unchanged
TEACH-IN mode of operation (E2/E3)
rising ramp
falling ramp
zero line
on
on
on
off
off
off
off
flashing
flashing (syn-
chronised)
flashing
off
flashing (syn-
chronised)
unchanged
Normal mode
temperature compensated
plug pulled/shorted
on
off
off
on
on, if target in
evaluation
range
on, if target in
detection range
analogue value
Standby flashing off previous state previous state unchanged
Interference (e.g. compressed air) off flashing previous state previous state unchanged or
error value
A1 A2
E2 E3
LED
yellow
Dual-LED
green/red
LED
yellow
Evaluation limit 1
"Power on"/Disturbance
Evaluation limit 2
LED-Window
RS 232-connection
LED-window
V15-plug connector
(M12x1)
1: TXD
2: RXD
3: not used
4: GND
Temperature/program
connector
(PC connection via inter-
face cable UC-30GM-R2)
Groove
1
2
4
3