Datasheet
Ultrasonic sensor UB800-18GM40A-I-V1
3
Release date: 2016-04-25 09:26 Date of issue: 2016-04-25 205341_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -U
B
or +U
B
to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -U
B
, A2 with +U
B
.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - U
B
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + U
B
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + U
B
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - U
B
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
LED Displays
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN evaluation limit
Object detected
No object detected
Object uncertain (TEACH-IN invalid)
off
flashes
on
flashes
off
off
Normal mode (evaluation range) off on
Fault on previous state