Datasheet

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Ultrasonic sensor UB4000-F42-E5-V15
4
Release date: 2009-10-22 13:22 Date of issue: 2009-10-22 134000_ENG.xml
Two modes are possible:
Several sensors are controlled via the same synchronisation signal. The sensors work in common mode.
The synchronisation pulses are forwarded at cyclic intervals to respectively one single sensor. The sensors work in multiplex mode.
Self-synchronisation:
The synchronisation ports of up to 5 sensors suitable for self-synchronisation are connected to each other. These sensors work
in multiplex mode after Power on. The On delay increases depending on the number of sensors to be synchronised. While the
learn mode is active, no synchronisation is possible (and vice-versa). To specify the switching points, the sensors must be op-
erated in non-synchronised mode.
Note:
If the synchronisation option is not used, the synchronisation input must be connected to ground (0V) or the sensor must be
operated with a (4-pole) V1 connecting cable.