Datasheet
Ultrasonic sensor UB400-12GM-E5-V1
3
Release date: 2017-07-12 08:57 Date of issue: 2017-07-12 114846_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage
-U
B
or +U
B
to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whe-
ther the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with -U
B
, A2 with +U
B
.
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Set target to far switching point
- TEACH-IN switching point A2 with +U
B
TEACH-IN window mode, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Set target to far switching point
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-open function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with +U
B
TEACH-IN detection of objects presence
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
B
- TEACH-IN switching point A2 with +U
B
LED Displays
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the
mounting flanges BF 12, BF 12-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole, it has to be
fixed at the middle of the housing thread.
Accessories
UB-PROG2
Programming unit
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
BF 12
Mounting flange, 12 mm
BF 12-F
Mounting flange with dead stop, 12 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
UVW90-M12
Ultrasonic -deflector
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN switching point:
Object detected
No object detected
Object uncertain (TEACH-IN invalid)
off
flashes
On
flashes
off
off
Normal operation off Switching state
Fault on Previous state