Datasheet

Operating data
Detection range 0.3 m … 4 m, for liquids
Accuracy 0.5 % of the measuring area terminal value
Resolution 2 mm
Electrical data
Operating voltage 20 V DC … 30 V DC
Analogue output 4 mA … 20 mA
and 0 V … 20 V
Mechanical data
Ambient temperature 248 Kelvin … 343 Kelvin (-25 °C … +70 °C)
Protection IP65
Method of connection V15 plug connector (M12 x 1), 5-pin
Dimensions L 126 mm, Ø 44 mm
Process connection (Order code):
Screwed connection G1
1
/
2
A, high-grade steel 1.4571 LUC4T-G5S-IU-V15
Screwed connection G1
1
/
2
A, Polypropylene LUC4T-G5P-IU-V15
Screwed connection G1
1
/
2
’NPT, high-grade steel 1.4571 LUC4T-N5S-IU-V15
Screwed connection G1
1
/
2
’NPT, Polypropylene LUC4T-N5P-IU-V15
Operating data
Detection range 60 mm… 550 mm
Unusable are 0 mm … 60 mm
Response time 10 s
Electrical data
Operating voltage 10 VDC … 252 VDC
20 VAC … 252 VAC, 47 Hz … 63 Hz
Mechanical data
Working temperature 253 Kelvin … 333 Kelvin (–20 °C … + 60 °C)
Protection IP65
Method of connection V7 plug connector, 7-pin
Dimensions L 107 mm, Ø 75 mm
Process connection (Order code):
3 relay outputs, N.0./N.C. UC500-D1-3K-V7
Ultrasonic level sensor
Series -D1- with
3 relay outputs,
temperature
compensated
9
Ultrasonic
level sensor
Series LUC- with
analogue output and
active moving-target
indication, temperature
compensated