Datasheet

Operating data
Detection range 60 mm … 500 mm 300 mm … 3000 mm 800 mm … 6000 mm
Unusable area 0 mm … 60 mm 0 mm … 300 mm 0 mm … 800 mm
Electrical data
Operating voltage 20 V DC … 30 V DC
Temperature compensation a temperature signal is available at the temperature output for external temperature compensation.
Determination the determination of the detection range is carried out by the control unit electronics
(e.g. units UH3-KHD2-4E5, UH3-KHD2-4I or UH3-T1-KT);
in pulse-echo operation the detection range is derived from the emitter pulse propagation time.
Mechanical data
Ambient temperature 248 Kelvin … 343 Kelvin (-25 °C … +70 °C)
Protection IP65
Method of connection terminal housing, M20, core cross section 2.5 mm
2
Dimensions L x W x H 128 mm x 40 mm x 40 mm 128 mm x 40 mm x 40 mm 61 mm x 80 mm x 80 mm
Version (Order code):
Transceiver UB500+U9+H3 UB3000+U9+H3 UB6000-FP-H3
Series VariKont/FP
in direct detection mode
Series VariKont Series VariKont Series FP
Operating data
Detection range 60 mm … 500 mm
Unusable area 0 mm … 60 mm
Electrical data
Operating voltage 10 V DC … 30 V DC
Determination the determination of the detection range is carried
out by the control unit electronics;
in pulse-echo operation the detection range
is derived from the emitter pulse propagation time.
Mechanical data
Ambient temperature 248 Kelvin … 343 Kelvin (-25 °C … +70 °C)
Protection IP65
Method of connection plug connector V1 (M12 x 1), 4-pin
Dimensions 25 mm x 105 mm x 31 mm
Version (Order code):
Transceiver UB500-F54-H3-V1
Series -F54-
in direct detection mode
23