Datasheet

Technical data
Detectable paper thickness 10 g/m
2
… 2000 g/m
2
Response time 15 ms*
Electrical data
Rated operating voltage 20 V DC … 30 V DC
Mechanical data
Ambient temperature 0 °C … +60 °C
Protection class IP67
Connection 2 m cable
Switch outputs 3 x pnp
normally-closed
Dimensions L 74 mm / 22 mm, Ø 18 mm
Range of application (Order code):
Double sheet detection UDC-18GM-400-3E3
Applications:
In printing machinery, where the ultrasonic double
sheet control protects the complex mechanics from
damage and prevents a second sheet from lodging
in the machine, by avoiding the situation in which
two sheets are drawn into it.
Additional application through series 18GM35:
In the control of adhesive films in label making
machines, in which the application of the films to a
carrier material can be detected and counted.
In letter opening equipment, where the complete
emptying of the opened envelope is controlled.
In receipt and voucher counting machines, in which
the ultrasonic double sheet control ensures that
bank receipts are not counted incorrectly.
In packaging machines, in which the jointing posi-
tions for the connection of an aluminium packaging
film to the beginning and the end of a sheet are
detected and the running speed of the machine is
adjusted accordingly.
In paper processing machinery, for the detection of
air, single and double sheets and/or jointing
positions.
In paper sorting systems in the manufacture of
calenders no monthmust be missing or
inserted twice.
21