Datasheet
14
Operating data
Detection range 30 mm … 500 mm 60 mm … 2000 mm 200 mm … 4000 mm
Unusable area 0 mm … 30 mm 0 mm … 60 mm 0 mm … 200 mm
Response time approx. 50 ms approx. 150 ms approx. 325 ms
Resolution max. 0.2 mm 0.35 mm (at max. detection range) 0.35 mm (at max. detection range)
Setting the evalution limits and output functions with two button keypad
Electrical data
Operating voltage 10 V DC … 30 V DC
15 V DC … 30 V DC (sensors with voltage output)
Mechanical data
Working temperature 248 Kelvin … 343 Kelvin (-25 °C … +70 °C)
Protection class IP65
Method of connection V15 plug connector (M12x1), 5-pin
Dimensions L x W x H 34 mm x 80 mm x 80 mm
Outputs (Order code):
Analogue output 4 mA ... 20 mA UB500-F42-I-V15 UB2000-F42-I-V15 UB4000-F42-I-V15
(Falling/rising slope selectable)
Analogue output 0 V … 10 V UB500-F42-U-V15 UB2000-F42-U-V15 UB4000-F42-U-V15
(Falling/rising slope selectable)
Series - F42-
with analogue output,
temperature compensated,
synchronisation input
Operating data
Detection range 30 mm … 500 mm 60 mm … 2000 mm
Unusable area 0 mm … 30 mm 0 mm … 60 mm
Response time approx. 50 ms approx. 150 ms
Resolution 0.2 mm (at max. detection range) 0.7 mm (at max. detection range)
Setting the evalution limits and output functions with two button keypad
Electrical data
Operating voltage 10 V DC … 30 V DC
15 V DC … 30 V DC (sensors with voltage output)
Mechanical data
Working temperature 248 Kelvin … 358 Kelvin (-25 °C … +70 °C)
Protection class IP65
Method of connection V15 plug connector (M12x1), 5-pin
Dimensions L x W x H 80 mm x 34 mm x 80 mm
Outputs (Order code):
Analogue output 4 mA ... 20 mA UB500-F42S-I-V15 UB2000-F42S-I-V15
(Falling/rising slope selectable)
Analogue output 0 V … 10 V UB500-F42S-U-V15 UB2000-F42S-U-V15
(Falling/rising slope selectable)
Series - F42-
with analogue output,
temperature compensated,
synchronisation input
■ Disturbing target suppression
■ Adjustable sensitivity
■ Disturbing target suppression
■ Adjustable sensitivity
Ultrasonic Sensors