Datasheet

Operating data
Detection range 60 mm … 500 mm 300 mm … 3000 mm 800 mm … 6000 mm
Unusable area 0 mm … 60 mm 0 mm … 300 mm 0 mm … 800 mm
Response time 30 ms 120 ms 270 ms
Setting the switching points
and output functions (N.O.) with DIP switch or RS 232
Electrical Data
Operating voltage 20 V DC … 30 V DC
Mechanical Data
Ambient temperature 248 Kelvin … 343 Kelvin (-25 °C … +70 °C)
Protection IP65
Method of connection Terminal housing, Pg 13.5, core cross-section 2.5 mm
2
Dimensions 128 mm x 40 mm x 40 mm 128 mm x 40 mm x 40 mm 61 mm x 80 mm x 80 mm
Serial Interface RS 232 interface (Parameterisation with Windows-Software Ultra 2001)
Operating modes switching point mode
window mode
hysteresis mode
reflex mode
area monitoring
Outputs (Order code):
Switch output 1 und 2, pnp, N.O./N.C. UC500+U9+E6+R2 UC3000+U9+E6+R2 UC6000-FP-E6-R2-P5
Switch ouput 1 und 2, npn, N.O./N.C. UC3000+U9+E7+R2 UC6000-FP-E7-R2-P5
Series VariKont/FP
with serial interface and
two switch outputs,
temperature compensated,
synchronisation input
Operating data
Detection range 300 mm … 3000 mm 800 mm … 6000 mm
Unusable area 0 mm … 300 mm 0 mm … 800 mm
Response time 100 ms 270 ms
Resolution 11 mm 1 LSB
1
21 mm 1 LSB
2
Electrical data
Operating voltage 20 V DC … 30 V DC
Mechanical data
Ambient temperature 263 Kelvin … 323 Kelvin (-10 °C … +50 °C)
Protection IP65
Method of connection 2 m cable, 14 x 0.14 mm
2
Dimensions L x W x H 128 mm x 40 mm x 40 mm 61 mm x 80 mm x 80 mm
Serial interface RS 232 interface (Parameterisation with Windows-Software Ultra 2001)
Outputs (Order code):
8 Bit output, error output,
Test input UJ3000+U1+8B+RS UJ6000-FP-8B+RS
Series VariKont/FP
with serial Interface
and 8 bit output
Series VariKont
Series VariKont Series VariKont Series FP
Series FP
1)
with 300 mm … 3000 mm
detection range
2)
with 800 mm … 6000 mm
detection range
10
Ultrasonic Sensors