Inductive proximity switches
SC3,5-G-N0
PEPPERL+FUCHS GmbH www.pepperl-fuchs.com
6
2004-03-01 – 045585_ENG.xml
ATEX 3G (nL)
Instruction Manual electrical apparatus for hazardous areas
Device category 3G (nL) for use in hazardous areas with gas, vapour and mist
Directive conformity 94/9/EG
Standard conformity EN 50021:2000 Ignition protection category "n"
Use is restricted to the following stated conditions
CE symbol
0102
Ex-identification ¬ II 3G EEx nL IIC T6 X
Effective internal capacitance C
i
150 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
150 µH ; a cable length of 10 m is considered.
General The apparatus has to be operated according to the appropriate data in the data
sheet and in this instruction manual. The data stated in the data sheet are
restricted by this operating instruction! The special conditions must be
observed!
Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage
goal must be observed. The sensor must only be operated with an energy-lim-
ited circuit, which satisfies the requirements of IEC 60079-15. The explosion
group complies with the connected, supplying, power limiting circuit.
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
[Fett]Special conditions
Maximum permissible ambient temperature T
Umax
at Ui = 20 V
for Pi=34 mW, Ii=25 mA, T6 66 °C
for Pi=34 mW, Ii=25 mA, T5 81 °C
for Pi=34 mW, Ii=25 mA, T4-T1 100 °C
for Pi=64 mW, Ii=25 mA, T6 66 °C
for Pi=64 mW, Ii=25 mA, T5 81 °C
for Pi=64 mW, Ii=25 mA, T4-T1 100 °C
for Pi=169 mW, Ii=52 mA, T6 45 °C
for Pi=169 mW, Ii=52 mA, T5 60 °C
for Pi=169 mW, Ii=52 mA, T4-T1 89 °C
for Pi=242 mW, Ii=76 mA, T6 30 °C
for Pi=242 mW, Ii=76 mA, T5 45 °C
for Pi=242 mW, Ii=76 mA, T4-T1 74 °C
Protection from mechanical danger The sensor must not be mechanically damaged.
When used in the temperature range below -20°C the sensor should be pro-
tected from knocks by the provision of an additional housing.
Connection parts The connection parts are to be installed, such that a minimum protection class