Datasheet
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches
SC3,5-G-N0
PEPPERL+FUCHS GmbH www.pepperl-fuchs.com
4
2004-03-01 – 045585_ENG.xml
ATEX 1D
Instruction  Manual electrical apparatus for hazardous areas
Device category 1D  for use in hazardous areas with combustible dust
Directive conformity  94/9/EG
Standard conformity  IEC 61241-11:2002: draft; prEN61241-0:2002 
type of protection intrinsic safety "iD" 
Use is restricted to the following stated conditions
CE symbol 
0102
Ex-identification  ¬ II 1D Ex iaD 20 T 108 °C
EC-Type Examination Certificate  ZELM 03 ATEX 0128 X
 Assigned type  SC3,5...-N0...
 Effective internal capacitance C
i
  ≤ 150 nF ; a cable length of 10 m is considered.
 Effective internal inductance L
i
  ≤ 150 µH ; a cable length of 10 m is considered.
General  The apparatus has to be operated according to the appropriate data in the data 
sheet and in this instruction manual. 
The EU prototype test certificate must be observed. 
The special conditions must be adhered to!
Maximum housing surface temperature  The maximum surface temperature of the housing is given in the EC-Type 
Examination Certificate.
Installation, Comissioning  Laws and/or regulations and standards governing the use or intended usage 
goal must be observed. 
The intrinsic safety is only assured in connection with an appropriate related 
apparatus and according to the proof of intrinsic safety. 
The associated apparatus must satisfy at least the requirements of category ia 
IIB or iaD. Because of the possibility of the danger of ignition, which can arise 
due to faults and/or transient currents in the equipotential bonding system, gal-
vanic isolation in the power supply and signal circuits is preferable. Associated 
apparatus without electrical isolation must only be used if the appropriate 
requirements of IEC 60079-14 are met. 
The intrinsically safe circuit has to be protected against influences due to light-
ning. 
When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und 
Zone 22 the sensor must not be exposed to any mechanical danger and must 
be sealed in such a way, that the protective function of the isolating wall is not 
impaired. The applicable directives and standards must be observed.
Maintenance  No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions   
Electrostatic charging  The connection cables are to be laid in accordance with EN 50281-1-2 and must 
not normally be subjected to chaffing during use. 