Datasheet

Inductive positioning system PMI80-F90-IU-V1
2
Release date: 2014-09-02 09:58 Date of issue: 2016-03-17 191134_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Operating instructions
Safety information
Sensor versions
The F90 linear position measurement system is available in 2 versions.
In the PMI...-F90-IU-V1 version, the position measuring system transmits current and voltage signals pro-
portional to the position of the damping element at the outputs.
The PMI...-F90-IE8-V15 version offers a current signal as well as the option of teaching in two switching
points directly at the sensor independently of one another at the press of a button, which is then indicated
on two switching outputs. Two additional LEDs indicate the output states of the two switching outputs.
Version PMI…-F90-IU-V1
Output signals: 4 mA ... 20 mA and 0 V ... 10 V
Version PMI…-F90-IE8-V15
Output signals: 4 mA ... 20 mA and 2 programmable switching amplifiers
Programming the PMI…-F90-IE8-V15
The rear of the PMI...-F90-IE8-V15 sensor has two small, slightly recessed push buttons for programming
the switching points. The buttons are marked "teach in" and S1 for switching point S1 and S2 for switching
point S2.
To teach in a switching point, proceed as follows:
- The position detection damping element must be placed at the relevant position, i.e. the switching point
that you wish to teach in.
- Press the corresponding push button for at least two seconds.
The associated switching state LED starts flashing to indicate that the sensor is now in “teach mode”.
- Press the button again to confirm the relevant switching point.
The switching state LED then lights up constantly as long as the damping element is not moved.
The switching point is now taught in and the associated switching point changes to an active state within an
actuator adjustment range of ± 1 mm around the taught switching point.
Damping element
The linear position measurement system is adapted perfectly to
the geometry of the damping elements offered in our product
range.
Installation and operation
Pinout
Accessories
BT-F90-W
Damping element; lateral screw holes
MH-F90
Mounting bracket for mounting of F90 sensors
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
This product may not be used in applications where personal safety
depends on the function of the device.
This product is not a safety component as described in EU Machinery Direc-
tive.
Only the current output or the voltage output may be used. The unused output must remain
load free.
If the switching point is not confirmed within 80 seconds, the sensor exits “teach mode” and
continues operation with the previous values.
When using other damping elements, always make
sure that the active surface of the damping element
has a width of exactly 8 mm and covers the entire width
of the sensor.
1
3
4
2
1 BN
2 WH
3 BU
4 BK
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
Warning
Note
Note
≥ 4
8
≥ 18
Note
Additional Information
≥ 4
8
≥ 18
dimensions for the target object:
Linearity range
Measuring range
10 V/20 mA
0 V/4 mA