Datasheet

Inductive positioning system PMI14V-F112-2EP-IO-V31
3
Release date: 2013-12-11 15:40 Date of issue: 2013-12-11 247164_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Actuator
The linear position measurement system is optimally aligned to the geometry of Pepperl+Fuchs actuators.
Using Your Own Actuators
Generally speaking, it is possible for you to use your own actuators. The specified measurement accuracy of the sensor will be achieved
only if the actuator has the following properties:
Material: construction steel such as S235JR+AR (previously St37)
Dimensions (L x W x H): >
18 mm x 8 mm x > 4 mm
The active surface of the actuator must protrude across the entire sensor width.
Note:
The width of the actuator must be precisely 8 mm. If the width of the actuator deviates from this value, the position values will differ.
Installation
It is possible to flush mount the device.
The distance between the center of the measurement field (framed area on the front panel of the sensor) and the fixing base or fixing
elements (e.g., protruding screw heads) of the actuator must be at least 10 mm.
Operating Instructions
The specified measurement accuracy is achieved if the distance of the actuator from the sensor surface is max. 2.5 mm.
Definition of the Measuring Range/Measured Position
The measured position of the actuator is based on half of the width (center of the actuator).
The measuring range starts and ends when the actuator covers the measurement field marked on the sensor with half of its width in the
course of its longitudinal movement.
Supported IO-Link device parameters
Details of the listed device parameters can be found in the manual.
Index Subindex Name
Smart sensor profile parameters
0x3A Teach-In Channel
0x3B Teach-In Status
0x3C 1, 2 BD1_SPV, Switching signal 1
0x3D 1, 2, 3 BD1_SPV, Switching signal 1 configuration
0x3E 1, 2 BD2_SPV, Switching signal 2
0x3F 1, 2, 3 BD2_SPV, Switching signal 2 configuration
0x4000 1, 2 BD3_SPV, Switching signal 3
0x4001 1, 2, 3 BD3_SPV, Switching signal 3 configuration
Device specific operation parameters
0x40 1, 2, 3 Centered Window Width
0x42 1, 2 AD_SPC, Analog signal setpoint value
0x43 1, 2, 3 AD_SPC, Analog signal configuration
0x5F 1, 2, 3, 4, 5 Measurement data collection
Standard operation control
0x70 1, 2, 3, 4, 5, 6, 7, 8 Output configuration
0x74 Event configuration
0x7F Locator indication control
User information
0xC0 UT1, User tag 1
0xC1 UT2, User tag 2
Special function
0xE2 Operating temperature
0xE8 1, 2 Device characteristics
start of measuring range measured position end of measuring range
labeled measuring area
motion direction of actuator
width w of actuator
w/2
actuator