Datasheet
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Inductive sensor NCN3-F31-N4-V1
4
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223957_eng.xml
Equipment protection level Gb
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
NCN3-F31-N4...
ATEX certificate
TÜV 99 ATEX 1479 X
ATEX marking
¬ II 1G Ex ia IIC T6…T1 Ga
Standards
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificate
IECEx TUN 17.0021X
IECEx marking
Ex ia IIC T6...T1 Ga
Standards
IEC 60079-0:2011 , IEC 60079-11:2011
Effective internal inductivity C
i
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Effective internal inductance L
i
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 15 V , I
i
= 25 mA , P
i
= 34 mW ,
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 15 V , I
i
= 25 mA , P
i
= 64 mW ,
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 15 V , I
i
= 52 mA , P
i
= 169 mW ,
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)
Equipment protection level Gc (ic)
Type of protection intrinsic safety
CE marking
Certificates
ATEX certificate
PF13CERT2895 X
ATEX marking
¬ II 3G Ex ic IIC T6…T1 Gc
Standards
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
Effective internal inductivity C
i
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Effective internal inductance L
i
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 20 V , I
i
= 25 mA , P
i
= 34 mW ,
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 20 V , I
i
= 25 mA , P
i
= 64 mW ,
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 20 V , I
i
= 52 mA , P
i
= 169 mW ,
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)