Copyright Pepperl+Fuchs
ATEX 1G
Instruction Manual electrical apparatus for hazardous areas
Device category 1G
for use in hazardous areas with gas, vapour and mist
Directive conformity 94/9/EG
Standard conformity EN 60079-0:2009, EN 60079-11:2007, EN 60079-26:2007
Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
CE marking 0102
Ex-identification ¬ II 1G Ex ia IIC T6 Ga
EC-Type Examination Certificate PTB 00 ATEX 2048 X
Appropriate type
NCB1,5...M...N0...
Effective internal capacitance C
i
≤ 90 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
≤ 100 µH ; a cable length of 10 m is considered.
Cable length Dangerous electrostatic charges on the fixed connection cable must be taken into
account for lengths equal to and exceeding the following values:
Explosion group IIA 147 cm
Explosion group IIB 73 cm
Explosion group IIC 11 cm
General The apparatus has to be operated according to the appropriate data in the data
sheet and in this instruction manual.
The EC-Type Examination Certificate has to be observed. The special conditions
must be adhered to!
Directive 94/9/EG and hence also EC-Type Examination Certificates apply in gene-
ral only to the use of electrical apparatus under atmospheric conditions.
The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces
by the mentioned certification authority.
If the equipment is not used under atmospheric conditions, a reduction of the per-
missible minimum ignition energies may have to be taken into consideration.
Highest permissible ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type
Examination Certificate. Note: Use the temperature table for category 1 !!! The 20
% reduction in accordance with EN 1127-1:2007 has already been accounted for in
the temperature table for category 1.
Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal
must be observed.
The intrinsic safety is only assured in connection with an appropriate related
apparatus and according to the proof of intrinsic safety.
The associated apparatus must satisfy the requirements of category ia.
Due to the possible danger of ignition, which can arise due to faults and/or transient
currents in the equipotential bonding system, galvanic isolation of the power supply
and signal circuit is preferable. Associated apparatus without electrical isolation
must only be used if the appropriate requirements of IEC 60079-14 are met.
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Specific conditions
Protection from mechanical danger
When used in the temperature range below -20 °C the sensor should be protected
from knocks by the provision of an additional housing.
Electrostatic charging
Electrostatic charges must be avoided on the mechanical housing components.
Dangerous electrostatic charges on the mechanical housing components can be
avoided by incorporating these in the equipotential bonding.