Equipment protection level Dc (tD)
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with non-conducting combustible dust
CE marking
ATEX marking ¬ II 3D Ex tD A22 IP67 T80°C X
Standards EN 61241-0:2006, EN 61241-1:2004
Protection via housing "tD"
Use is restricted to the following stated conditions
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment.
The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be adhered to!
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed.
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current I
L
The maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage U
Bmax
The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are
not permitted.
Maximum permissible ambient tempera-
ture T
Umax
dependant of the load current I
L
and the max. operating voltage U
Bmax
Information can be taken from the following list.
at U
Bmax
=30 V, I
L
=200 mA
55 °C (131 °F)
at U
Bmax
=30 V, I
L
=100 mA
58 °C (136.4 °F)
Protection from mechanical danger
The sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV light
The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is
used in internal areas.
Electrostatic charge
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the
mechanical housing components can be avoided by incorporating these in the equipotential bonding.
Sliding contact discharges must be avoided.
Plug connector
The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT
SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e.
the area that is inaccessible when the connector is inserted)
The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting