Cut Sheet

Photoelectric
MP Series Modular
Photoelectric Sensors
613
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776-4411
fa-info@de.pepperl-fuchs.com
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Subject to modifications without notice Copyright Pepperl+Fuchs
Wiring Diagrams
AC
Terminal Connection Cable Connection
Model:MPS10HD
Model:MPS11HD
Model:MPS12HD
Model:MPS13HD
Model:MPS17HD
Model:MPV11HD
Model:MPV12HD
Model:MPV13HD
Model:MPSD11HD
Model:MP2S11HD
Green (Metal Base Only)
AC
1
2
3
4
L1
N
Green (Metal Base Only)
A
C
1
2
3
4
L1
N
Relay Output
NOTE: Pins 3 and 4 must be
jumpered (jumper wire not included)
Green (Metal Base Only)
A
C
1
2
3
4
L1
L2
Relay Output
NOTE: Pins 3 and 4 must be
jumpered (jumper wire not included)
Green (Metal Base Only)
AC
1
2
3
4
L1
L2
Green (Metal Base Only)
A
C
1
2
3
4
L1 115V AC
N
L2(-/+)
L1(+/-) 115-300V AC/DC
Load
AC
1
2
NO
C
NC
L1
N.O.
COM.
N.C.
N
AC
1
2
NO
C
NC
L1
N.O.
COM.
N.C.
L2
AC
1
2
NO
C
NC
L1 24 VAC
N.O.
COM.
N.C.
N
Green (Metal Base Only)
AC
1
3
2
4
7
6
8
5
L1
N.O.1
COM.1
N.C.1
N
N.O.2
COM.2
N.C.2
Green (Metal Base Only)
AC
1
2
3
4
L1 20-260 VAC
L2
Load
DC
Terminal Connection
Model:MPS30HD
Model:MPS31HD
Model:MPS32HD
Model:MPS33HD
Model:MPV31HD
Green (Metal Base Only)
DC
1
2
3
4
(-)
(+)
Green (Metal Base Only)
DC
1
2
3
4
(-)
(+)
Load
Load
Green (Metal Base Only)
DC
1
2
3
4
(-)
(+)
Load
Green (Metal Base Only)
DC
1
2
3
4
(-)
(+)
Load
Load
DC
1
2
NO
C
NC
(+)
N.O.
COM.
N.C.
(-)
Model:MPS35HD
Green (Metal Base Only)
DC
Analog
1
2
3
4
(-)
(+)
I Load
V Load
AC/DC
Terminal Connection
Model:MPS16HD
Model:MPS18HD
Model:MPV14HD
AC/DC
1
2
3
4
L1(+/-) 24V AC/DC
N(-/+)
L2(-/+)
L1(+/-) 24-300V AC/DC
Load
Green (Metal Base Only)
AC/DC
1
2
3
4
L1(+/-) 12-140V AC/DC
N(-/+)
N(-/+)
L1(+/-) 12-140V AC/DC
Load
AC/DC
1
2
NO
C
NC
L1(+/-) 20-260 VAC/DC
N.O.
COM.
N.C.
L2(-/+)
AC
Model:MPT10HD
Model:MPT11HD
Model:MPT17HD
Model:MPW11HD
Model:MP2T11HD
AC
Black
White
L1
N
AC
Black
Red
Orange
White
L1
Relay Output
N
NOTE: Relay also requires AC power
AC
Black
Red
Orange
White
L1 115 VAC
L1 (+/-)115-300V AC/DC
N
L2 (-/+)
Load
AC
Black
White
Orange
Red
Blue
L1
N.O.
COM.
N.C.
N
AC
Black
White
N
L1
Load
Cable Connection
DC
Model:MPT30HD
Model:MPT31HD
Model:MPT32HD
Model:MPT33HD
DC
Black
Red
(+)
(-)
DC
Red
Black
(-)
(+)
White
Load
DC
Red
Black
White
(-)
(+)
Load
DC
Orange
Red
Black
White
(-)
(+)
Load
Load